PAM Distillation full automatic distillation
Precision Automated Manual Distillation Unit
 
   


> True Stand alone operation
> Fully automated operation
> True volume measurement
   (without volume correction factors)
> Programmable with 'learn' feature
> Digital distillation temperature measurement
> Auto Cal Temperature probe
   (with built in calibration data memory)
> Dynamic ASTM 7C/F and ASTM 8C/F thermometer simulation
> Automatic barometric pressure correction
   (with built in pressure sensor)
> Automatic final boiling point detection and loss correction
> Solid state condenser tube cooling via Peltier elements
> Solid state receiver compartment cooling via Peltier elements
> Data port for data output to PC (LIMS)
> Printer port
> ORBIS Multipurpose Flask Support Board

 
Go Back
282kb
Info page

Download our full
Distillation Catalogue

   
     
ORBIS BV PAM Distillation The ORBIS PAM-Distillation is the final result of the "ORBIS Basic Line" Distillation Units.Well devised and succesfully tested Unique details of this Full Automatic Distillation Unit are for instance:

NEW ORBIS revolutionary "Volume-Scan" System

is accurately measuring the true recovered volume at the bottom line of the meniscus, eliminating volume measurement errors. Ring marks on receivers do not disturb the volume measurement using this technique - Automatic calibration of the volume measuring system is performed before each distillation start - Solid-state volume detection and receiver cooling technique. - Recovered volume and receiver temperature is displayed on a large display at the front panel of the receiver compartment.
ORBIS Dynamic Mercury Thermometer Simulation
the unique ORBIS dynamic simulation model ensures that all temperature points are converted precisely to correspond with results obtained from ASTM 7C/F or ASTM 8C/F mercury in glass thermometers, the specified temperature standards for most distillation methods.
ORBIS Auto Temperature-Probe Detection
each temperature sensor contains a unique 'identifier', which stores calibration data specific to that sensor. In the event that the sensor must be replaced, relevant sensor data is automatically recognized and transferred to the distillation unit eliminating the risk of using wrong calibration data with an exchanged temperature probe and avoiding the need to re-program calibration data.
Stand-Alone Operation,
the PAM-Distillation is designed to fully operate without a separate PC. Distillation programs can be set up directly and data is stored in built in database. Printing and data transfer to host computer (LIMS) can be done after successful distillation or from the integral database at the time it is required.
Barometric Pressure Correction
an integral electronic precision barometer compensates for changes in ambient pressure and automatically corrects volume/temperature point readings.
Automatic Loss Correction
Automatic Loss Correction is achieved by simply entering the residue and recovery data.
A low voltage heater module
is mounted directly into the flask support board for optimum heat transfer and energy efficiency. "Snap on" system means heater is easy and quick to replace in case needed.
Flask heating is displayed by a large display
located on the front panel of the heater unit. If required the heater temperature can be maintained manually for a manual operation of the distillation unit from here as well.
The heater module is controlled by an algorithm
that prevents pulsing during distillations ("Advanced Single-Cycle Switching Method")
The heat shield is double walled
and completely covers the flask neck as specified in the Method to protect the Flask neck from being cooled by the surrounding air.
Flask cooling is via a fan system
located below the flask heater, this allows rapid cooling of the flask after each test.
The heater unit has an integral spillage container
to safely retain the sample/broken glass in the event of flask breakage
The instrument incorporates the unique ORBIS Solid State Condenser System
that uses Peltier elements to control the temperature of the condenser tube. The condenser system has integral coolers and requires no external cooling system. The system operates without any liquids or moving parts and hardly requires any maintenance.
Condenser temperature is displayed by a large display
located on the front panel of the condenser unit. If required the condenser temperature can be maintained manually for a manual operation of the Distillation unit from here as well.
The condenser tube temperature
can be regulated for manual operation of the distillation unit between 0 - 60 °C and reaches 0°C in less than 10 minutes (at ambient of 25°C)
The Condenser Tube is made from high quality seamless stainless steel
and has a highly polished internal surface for reproducible liquid flow, enhanced repeatability and easy cleaning.
A unique "ORBIS BV Multipurpose Flask Support Board"
contains all 4 standard hole diameters and allows user to easily select flask support diameter according to his test requirement (with no need to take out the support board between distillations).
Full usable:
ORBIS PAM-Distillation can be operated as a Manual, Semi or Full Automatic Distillation unit.
Simple and straight forward operation,
with a single scroll button all menus are selected and required parameters are set quickly. Parameters are stored in Distillation programs for subsequent recall with the next distillation.
ORBIS Measuring Cylinders
fully made from glass with a closed bottom, eliminating the risk of leaking O-rings.
ORBIS Distillation Flasks
are manufactured precisely conform the test standards, each flask is marked with an individual serial number and supplied with a test certificate.

SUPPLIED WITH:
Multi purpose flask support board, Auto Cal Temperature Probe, 125ml NS 19/26 distillation flask, thermometer centring device, 100 ml receiver with 5 and 100ml ring-mark, and instruction manual.

Certification:
The temperature probe is supplied Factory Calibrated. A UKAS calibration service is available on request.



ORBIS Multipurpose
Flask support board


Quick snap
Heater mounting


ORBIS Liquid free
& Solid state cooling

Inside polished Condenser tube


ORBIS Volume scan
True volume reading


ORBIS Liquid free
& Solid state cooling
 
   
   

ORBIS BV
de Regge 32
8253 PG Dronten
The Netherlands

Phone: +31-321 382354
Fax: +31-321 382357
Email: info@orbisbv.com

 

ORBIS BV PAM Distillation
ORBIS BV - Egon Bruggeman
atmospheric, distillation, PAM, volume scan, precise, ASTM D86, ASTM D850, ASTM D1078, ASTM E133, IP 123, IP 191, IP 195, EN 3405, BS 2000, BS 658, BS 7392, ISO 198, NF M07-002, JIS K2254, ORBIS BV,
atmospheric, distillation, PAM, volume scan, precise, ASTM D86, ASTM D850, ASTM D1078, ASTM E133, IP 123, IP 191, IP 195, EN 3405, BS 2000, BS 658, BS 7392, ISO 198, NF M07-002, JIS K2254, ORBIS BV,
atmospheric, distillation, PAM, volume scan, precise, ASTM D86, ASTM D850, ASTM D1078, ASTM E133, IP 123, IP 191, IP 195, EN 3405, BS 2000, BS 658, BS 7392, ISO 198, NF M07-002, JIS K2254, ORBIS BV,